Profile
Objective:
To develop a reliable cable/connector combination for Profinet with harmonised components
Requirements:
Customers would like to use the high-quality components from both companies. However, they also need a clear statement about the reliable combination of the two components.
Industry: Machine & plant operator
Success for the customer:
Thanks to the collaboration between the product specialists (Katharina Esch from igus and Bianca Ulmschneider from Telegärtner) and their teams, a reliable Profinet connection was qualified that goes far beyond any standards. With this result, even the most demanding customer can be sure of combining the highest quality components, which are significantly above the market standard, in a functionally reliable manner.
The test procedure:
M12 circular connectors (D-coded) STX M12x1 KS were professionally assembled with the CFBUS.060 Profinet cable and measured using data transmission. After the successful test, the cable with the connector was stressed in motion and regularly re-measured. The large igus test laboratory was used to mechanically stress the cables in a real application. After completion of the endurance test, the complete test specimens were measured for their high-frequency behaviour at Telegärtner and assessed as positive.